strain gage animation

Japanese

"DS-7000" / Digital Transducer Indicator

Transducer Indicator DS-7000

Features

  • Low-cost, and standard specifications include top and bottom setting and holding functions.
  • Can match with all sorts of strain gage sensors through excitation voltage switching.
  • Indication with both polarities (±19999).
  • Check function of the sensor initial balance (±6000×10-6 in strain).
  • Capable of connecting in 4 parallel units of the 350Ω Series load cells.
  • High accuracy in non-linearity of 0.02%FS ± 1 digit.
  • Calibration methods for the strain gage sensor: Equivalent Input, Real Input, and TEDS.
  • Addition of various optional features is possible.

Related products : DS-6000

Specifications

Item Description
Sensor applied voltage DC10V,2.5V±10% Output current: within 120mA (30mA when using DC power supply option)
Sensor input range   -3.0 ~ +3.0 mV/V
Equivalent input and
TEDS
Calibration range: 0.3 ~ 3.0mV/V
Calibration accuracy: within 0.1%FS at setting range more than 0.5mV/V.
Zero Adj. range 0 ~ ±2.0mV/V
Minimum input sensitivity 1μV/count
Resolution: 1/10000 at input 1mV/V or more.
Accuracy Non-linearity: within 0.02%FS at input 3mV/V
Zero drift: within 0.5μV/℃ RTI
Gain drift: within 0.01%/℃
A/D converter Speed: 100 times/sec
Analog filter 4/10/100(default)/3kHz Selectable on the front panel
TEDS fubction IEEE1451.4 Class2 Mix Mode Interface
Peak hold function
(Analog and Digital Methods)
Response speed: Approx. 1kHz (wave width 2ms: input 3mV/V ,analog filter: 3kHz)
Accuracy: within 0.2%FS
Reset time: 50μs
Display Character hieght: 16mm 7segments Red LED, 5 digits numeric display
Display range: ±19999
Decimal point: selectable
Display rate: 3/6/13/25 times/sec, selectable
Display items Status(LED): HI,OK,LOW,PEAK,HOLD,CALIBRATION LOCK,SETTING LOCK
Setup items CAL setup: Zero CAL/Span CAL (Equivalent Input CAL, Real Load CAL, TEDS CAL)
Function setup: High Limit, Low Limit, High/Low Limit Comp. Mode, Hysteresis, Zero Vicinity, Digital Filter, Analog Filter, Motion Detect, Zero Tracking, Digital Zero, Zero Offset, Hold Mode, Key Lock, Minimum Scale, Display rate, Excitation Voltage, B.C.D. Refresh Rate, RS-232C, D/A Converter
External signal High/Low Limit Relay Contact Output, Analog Voltage Output, Hold Signal Input, Digital Zero Signal Input
Power supply AC85 ~ 264V 50/60 Hz, Approx.7W
DC10~28V(option), Approx.9W
Ambient condition Operation Temp.: -10 ~ +40℃
Strage Temp.: -40 ~ +80℃
Humidity: 80% RH or lower (no condensation)
External dimension 96 (W) x 96 (H) x 146 (D) mm(not including protruding parts)
Panel cut dimension 92 x 92 (+1-0)mm
Weight Approx. 1kg
Options DS-7000-OP3: B.C.D. Parallel Data Output
DS-7000-OP4: RS-232C Interface
DS-7000-OP7: D/A Converter (Voltage and Current Output)
*Refer to the instruction manual for the details
Accessories Operation Manual *1
Ac cable *1
B.C.D. Output Connector Plug 57-30360 DDK *1 (when an order for B.C.D. option is placed)
Ferrite Core *1 (when an order for B.C.D. option or D/A option is placed)

TEDS

By connecting a sensor complying with IEEE1451.4 (TEDS: Transducer Electronic Data Sheet), DS-7000 can retrieve the rated output values stored in the sensor, and applies them to the indicatorʼs calibration process. It also can save the self-calibrated values into the TEDS sensor.

Instruction Manual・・・・Download(pdf,708kB)

All the instruction nanuals are of Portable Documents Formats. For reading the instruction manual, it is necessary to be installed yourself in the Acrobat Reader of Adobe Company. Acrobat Reader is the registered trademark of Adobe Systems Co., Ltd.

get_adobe_reader

Home | About Us | Contact Us | Site Map... | tuochi Automatic Instrument Co.,Ltd  Tel: 021-51085998  Fax: 021-51069009  Mail: zhang@yanatoo.com